Jiangsu Acrel Electrical Manufacturing Co., Ltd.

AMC16-DETT Base Station DC Energy Meter For 5G Tower

● DC rated voltage: 1 channel: -48VDC

● Accuracy:1%In≤I≤10%In error±2.5%; I>10%In error±2%

● RS485(MODBUS-RTU)

● DIN 35 mm

● Designed for base stations


General

AMC16-DETT Base Station DC Energy Meter for 5G Tower is specially designed for base stations where have sharing requirements, and switch power supply is without the function of sub-user metering. The meter could measure 6 circuits DC energy, and supply working current to the matched hall sensors. Meanwhile, it can realize zero drift calibration by upper computer software. have the functions of telemetering, teleindication, teleadjusting, metering at real time, energy quality abnormal alarm, data storage and processing, data interaction.

Dimension

35.png

Installation

1667353038148931.jpg

Parameter
InputDC rated voltage1 channel: 0-48VDC
DC current

6 channels hall sensors: total 200A/5V, China Telecom, China Mobile, China

Unicom and the 1st channel reserve 50A/5V, 2nd channel reserve 100A/5V

Commercial power monitoring1 channel: 0-5VDC
Overload capacity

Voltage: 1.2 times continued, 2 times continued 1s;

Current: 1.2 times continued, 10 times continued 1s

Accuracy

(superposition hall sensors)

1%ln≤ l ≤10% ln error±2.5%; l>10%ln error±2%
Measurement resolutionVoltage: 0.01V, Current: 0.01A, Power: 0.01kw, Energy: 0.01kwh
FunctionsBasic functionMonitor device system time, total voltage, total current, power energy, each channel voltage, current, power, energy; LED display, RS485 communication
Metering function

Start current: under rated voltage, when the load current value of the meter doesn't exceed 1% of the max current,the meter start.

Shunt running current: when there is no current in the current circuit of the meter, and 85%-125% of the rated voltage is applied on the voltage circuit, the calculator shall not have more than one digital change.

Alarm functionDC under-voltage, DC over-voltage, one power down, module voltage loss, metering branch error, internal program error, clock error, memory failure, AC input power failure.


Get in touch with us!

Send us a message if you have any questions or request a quote. Our experts will give you a reply
within 24 hours and help you select the right products you want.

Hot Products
AKH-0.66/K-φ16 Split Core Current Transformer

AKH-0.66/K-φ16 Split Core Current Transformer

● AKH-0.66/K-Φseries split current transformers are mainly use... ● ···
AMC16-DETT Base Station DC Energy Meter For 5G Tower

AMC16-DETT Base Station DC Energy Meter For 5G Tower

● AMC16-DETT Base Station DC Energy Meter for 5G Tower is spec... ● ···
AHKC-EKA Open-loop Hall Effect Transducer (Split-core)

AHKC-EKA Open-loop Hall Effect Transducer (Split-core)

● Acrel AHKC series hall effect current sensor is mainly suita... ● ···
ADL3000-E or DTSD1352 Three-phase Multi-function DIN Rail Energy Meter

ADL3000-E or DTSD1352 Three-phase Multi-function DIN Rail Energy Meter

● ADL3000 is a smart meter designed for power supply system, i... ● ···